リケラボ論文検索は、全国の大学リポジトリにある学位論文・教授論文を一括検索できる論文検索サービスです。

リケラボ 全国の大学リポジトリにある学位論文・教授論文を一括検索するならリケラボ論文検索大学・研究所にある論文を検索できる

リケラボ 全国の大学リポジトリにある学位論文・教授論文を一括検索するならリケラボ論文検索大学・研究所にある論文を検索できる

大学・研究所にある論文を検索できる 「Ultrasound Speckle Tracking and Color Doppler Elastography for Quantitative Tissue Assessment」の論文概要。リケラボ論文検索は、全国の大学リポジトリにある学位論文・教授論文を一括検索できる論文検索サービスです。

コピーが完了しました

URLをコピーしました

論文の公開元へ論文の公開元へ
書き出し

Ultrasound Speckle Tracking and Color Doppler Elastography for Quantitative Tissue Assessment

Norma Hermawan 東北大学

2021.09.24

概要

This dissertation describes an implementation of speckle tracking algorithm for quantitative tissue assessment with clinical application in orthopedics for identifying Adhesive Capsulitis (AC) disease, and the method of mechanically induced shear wave elastography with a color Doppler imaging. The implemented speckle tracking software was capable of visualizing layers of tissue in the shoulder based on their velocity during a movement. In addition, Adhesion Index (AdI) quantity was introduced as a novel measure of shoulder adhesion, which was calculated from the velocity difference between subscapularis and the deltoid muscle of the shoulder. The result suggested that motion limitation on the AC patient could be explained by the AdI because the patient with restricted motion encountered a noticeable adhesion on the subscapularis. On the other part, a method of color Doppler elastography by mechanically induced shear wave is implemented. The capability of the method in resolving elasticity map of homogeneous and non- homogeneous phantom is demonstrated. Since it does not need a precise control to the imaging parameter, it can be implemented in standard commercially available ultrasound (US) machines. The measurement results suggested that the accurate estimation of the shear wave velocity was obtained. The merits of speckle tracking and mechanically induced shear wave elastography methods are that quantitative parameters of tissue character are obtained non-invasively and that all measurement data are obtainable by a standard ultrasound machine. Clinical application in the field of orthopedic surgery is desired in near future.

この論文で使われている画像

参考文献

[1] P. R. Hoskins, "Peak velocity estimation in arterial stenosis models using colour vector Doppler," Ultrasound in Medicine & Biology, vol. 23, no. 6, pp. 889-97, 1997.

[2] G. E. Trahey, J. W. Allison and O. T. v. Ramm, "Angle independent ultrasonic detection of blood flow," IEEE Trans Biomed Eng, vol. 34, no. 12, pp. 965-7, 1987.

[3] J. A. Jensen, "A new estimator for vector velocity estimation," IEEE Trans Ultrason Ferroelectr Freq Control, vol. 48, no. 4, pp. 886-94, 2001.

[4] K. Walker-Bone, K. P. Palmer, I. Reading, D. Coggon and C. Cooper, "Prevalence and Impact of Musculoskeletal Disorders of the Upper Limb in the General Population," Arthritis & Rheumatism, vol. 51, no. 4, pp. 642-651, 2004.

[5] K. Mezian and K.-V. Chang, "Shoulder, Frozen," National Taiwan University Hospital, 2018.

[6] R. Dias, S. Cutts and S. Massoud, "Frozen shoulder," BMJ, vol. 331, pp. 1453- 1456, 2005.

[7] A. Tandon, S. Dewan, S. Bhatt, A. K. Jain and R. Kumari, "Sonography in diagnosis of adhesive capsulitis of the shoulder: a case–control study," Ultrasound, vol. 20, p. 227–236, 2017.

[8] A. Ando, Y. Hagiwara, Y. Onoda, K. Hatori, H. Suda, E. Chimoto and E. Itoi, "Distribution of Type A and B Synoviocytes in the Adhesive and Shortened Synovial Membrane during Immobilization of the Knee Joint in Rats," The Tohoku Journal of Experimental Medicine, vol. 221, no. 2, pp. 161-8, 2010.

[9] W. H. Akeson, D. Amiel, M. F. Abel, S. R. Garfin and S. L.-Y. Woo, "Effects of Immobilization on Joints," Clinical Orthopaedics and Related Research, vol. 219, pp. 28-37, 1987.

[10] N. Hermawan, M. Fujiwara, Y. Hagiwara and Y. Saijo, "Visualization of Shoulder Ligaments Motion by Ultrasound Speckle Tracking Method," in 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Virtual, 2020.

[11] C.-H. Wu, W.-S. Chen and T.-G. Wang, "Elasticity of the Coracohumeral Ligament in Patients with Adesive Capsulitis of the Shoulder," Radiology, vol. 278, no. 2, pp. 458-464, 2016.

[12] B. K. Horn and B. G. Schunck, "Determining Optical Flow," Artificial Intelligence, vol. 17, pp. 185-203, 1981.

[13] B. D. Lucas and T. Kanade, "An Image Registration Technique with an Application to Stereo Vision," in 7th Intl Joint Conf on Artificial Intelligence (IJCAI), Vancouver, 1981.

[14] J. D'hooge, "Principles and Different Techniques for Speckle Tracking," in Myocardial Imaging: Tissue Doppler and Speckle Tracking, Malden, Oxford, Carlton, Blackwell Publishing, 2007, pp. 17-25.

[15] T. Koga, K. Linuma, A. Hirano, Y. Iijima, T. Ishiguro-OOnuma, Y. Lijima, M. Hirano and T. Ishiquro, "Motion-compensated interframe coding for video conferencing," in Proc. Nat. Telecommun. Conf., 1981, 1981.

[16] L.-K. Liu and E. Feig, "A Block-Based Gradient Descent Search Algorithm for Block Motion Estimation in Video Coding," IEEE Transaction on Circuits and Systems for Video Technology, vol. 6, no. 4, pp. 419-22, 1996.

[17] S. Zhu and K.-K. Ma, "A New Diamond Search Algorithm for Fast Block- Matching Motion Estimation," IEEE Transaction on Image Processing, vol. 9, no. 2, pp. 287-90, 2000.

[18] J. A. Nelder and R. Mead, "A Simplex Method for Function Minimization," The Computer Journal, vol. 7, no. 4, pp. 308-313, 1965.

[19] H.-C. Fei, C.-J. Chen and S.-H. Lai, "Enhanced Downhill Simplex Search for Fast Video Motion Estimation," in Advances in Multimedia Information Processing – PCM 2005. Lecture Notes in Computer Science, vol 3767., Berlin, Heidelberg, Springer, 2005, pp. 512-523.

[20] K. N. Ryu, S. W. Lee, Y. G. Rhee and J. H. Lim, "Adhesive Capsulitis of the Shoulde Joint: Usefulness of Dynamic Sonography," J Ultrasound Med, vol. 12, pp. 445-9, 1993.

[21] A. S. Neviaser and R. J. Neviaser, "Adhesive Capsulitis of the Shoulder," Journal of the American Academy of Orthopaedic Surgeons, vol. 19, pp. 536-542, 2011.

[22] D. S. Moore, G. P. McCabe and B. A. Craig, Introduction to the Practice of Statistics, New York: W. H. Freeman and Company., 2009.

[23] D. Giavarina, "Understanding Bland Altman analysis," Biochemia Medica, vol. 25, no. 2, p. 141–51, 2015.

[24] A. Yamamoto, K. Takagishi, T. Osawa, T. Yanagawa, D. Nakajima, H. Shitara and T. Kobayashi, "Prevalence and risk factors of a rotator cuff tear in the general population," Journal of Shoulder and Elbow Surgery, vol. 19, pp. 116-20, 2010.

[25] R. M. Lerner, K. J. Parker, J. Holen, R. Gramiak and R. C. Waag, "Sono- Elasticity: Medical Elasticity Images Derived from Ultrasound," in Acoustical Imaging, Boston, Springer, Boston, MA, 1988, pp. 317-327.

[26] Y. Yamakoshi, J. Sato and T. Sato, "Ultrasonic imaging of internal vibration of soft tissue under forced vibration," IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 32, no. 2, pp. 45-53, 1990.

[27] Y. Zheng, A. Yao, K. Chen, E. Zheng, T. Wang and S. Chen, "Impacts of the Capsule on Estimation of Shear Viscoelasticity of Livers," in IEEE International Ultrasonics Symposium Proceedings, 2011.

[28] H. L. Oestreicher, "Field and impendence of an oscillating sphere in a viscoelastic medium with an application to biophysics," Journal of Acoustical Society of America, vol. 23, pp. 707-14, 1951.

[29] D. C. Giancoli, Physics Principles with Applications 6th Ed., Upper Saddle River: Pearson Education, Inc., 2005.

[30] A. Anderson, "Doppler reflections," Physics Education, vol. 24, pp. 154-6, 1989.

[31] K. K. Shung, Diagnostic Ultrasound Imaging and Blood Flow Measurements, Boca Raton: CRC Press, 2006.

[32] J. A. Jensen, Estimation of Blood Velocities Using Ultrasound, A Signal Processing Approach, New York: Cambridge University Press, 1996.

[33] P. M. Embree and W. D. O'Brien, "The accurate ultrasonic measurement of the volume flow of blood by time domain correlation," in Ultrasonics Symposium Proceedings, 1985.

[34] P. M. Embree and W. D. O'Brien, "Volumetric blood flow via time-domain correlation: experimental verification," IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 37, no. 3, pp. 176-89, 1990.

[35] O. Bonnefous and P. Pesqué, "Time Domain Formulation of Pulse-Doppler Ultrasound and Blood Velocity Estimation by Cross Correlation," Ultrasonic Imaging, vol. 8, no. 2, pp. 73-85, 1986.

[36] C. Kasai, K. Namekawa, A. Koyano and R. Omoto, "Real-Time Two- Dimensional Blood Flow Imaging Using an Autocorrelation Technique," IEEE Transactions on Sonics and Ultrasonics, Vols. su-32, no. 3, pp. 458-464, 1985.

[37] Y. Yamakoshi, T. Kasahara, T. Iijima and Y. Yuminaka, "Shear Wave Wavefront Mapping Using Ultrasound Color Flow Imaging," Ultrasonic Imaging, vol. 37, no. 4, pp. 323-340, 2015.

[38] Z. Wu, L. S. Taylor, D. J. Rubens and K. J. Parker, "Sonoelastographic imaging of interference patterns for estimation of the shear velocity of homogeneous biomaterials," Physics in Medicine & Biology, vol. 49, no. 6, pp. 911-922, 2004.

[39] K. Hoyt, K. J. Parker and D. J. Rubens, "Real-time Shear Velocity Imaging Using Sonoelastographic Techniques," Ultrasound in Medicine & Biology, vol. 33, no. 7, pp. 1086-1097, 2007.

[40] M. S. T. G. Nightingale K, "Shear-wave generation using acoustic radiation force: in vivo," Ultrasound Med Biol., vol. 29, pp. 1715-23, 2003.

[41] S.-R. Huang, R. M. Lerner and K. J. Parker, "Time domain Doppler estimators of the amplitude of vibrating targets," The Journal of the Acoustical Society of America, vol. 91, no. 2, pp. 965-974, 1992.

[42] N. Hermawan, A. Sato, M. Fujiwara, T. Ishii, Y. Hagiwara, Y. Yamakoshi and Y. Saijo, "Binary Pattern Color Doppler Shear Wave Elastography (Accepted)," in 43rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Virtual, 2021.

[43] H. Morikawa, K. Fukuda, S. Kobayashi, H. Fujii, S. Iwai, M. Enomoto, A. Tamori, H. Sakaguchi and N. Kawada, "Real-time tissue elastography as a tool for the noninvasive assessment of liver stiffness in patients with chronic hepatitis C," Journal of gastroenterology, vol. 46, pp. 350-8, 2011.

[44] A. Itoh, E. Ueno, E. Tohno, H. Kamma, H. Takahashi, T. Shiina, M. Yamakawa and T. Matsumura, "Breast disease: clinical application of US elastography for diagnosis," Radiology, vol. 239, pp. 241-50, 2006.

[45] R. G. Barr and e. al., "WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 2: breast," Ultrasound in medicine & biology, vol. 41, pp. 1148-60, 2015.

[46] A. E. Samir, M. Dhyani, A. Anvari, J. Prescott, E. F. Halpern, W. C. Faquin and A. Stephen, "Shear-Wave Elastography for the Preoperative Risk Stratification of Follicular-patterned Lesions of the Thyroid: Diagnostic Accuracy and Optimal Measurement Plane," Radiology, vol. 277, pp. 565-73, 2015.

[47] R. M. S. Sigrist, J. Liau, A. E. Kaffas, M. C. Chammas and J. K. Willmann, "Ultrasound Elastography: Review of Techniques and Clinical Applications," Theranostics, vol. 7, no. 5, pp. 1303-29, 2017.

[48] J.-M. Correas, A.-M. Tissier, A. Khairoune, G. Khoury, D. Eiss and O. Hélénon, "Ultrasound elastography of the prostate: state of the art," Diagn Interv Imaging, vol. 94, no. 5, pp. 551-60, 2013.

[49] S. Paterson, F. Duthie and A. J. Stanley, "Endoscopic ultrasound-guided elastography in the nodal staging of oesophageal cancer," World J Gastroenterol, vol. 18, no. 9, pp. 889-95, 2012.

[50] K. S. Bhatia, Y. Y. Lee, E. H. Yuen and A. T. Ahuja, "Ultrasound elastography in the head and neck. Part II. Accuracy for malignancy," Cancer Imaging, vol. 13, no. 2, pp. 260-76, 2013.

参考文献をもっと見る

全国の大学の
卒論・修論・学位論文

一発検索!

この論文の関連論文を見る