Effects and dynamic characteristics of the core-suspended isolation system assessed by long-term structural health monitoring

中村 豊 Okada, Keiichi 島根大学 DOI:10.1002/eqe.3437

2021.07.21

概要

The seismic isolation mechanism of the core-suspended isolation (CSI) system comprises a double layer of inclined rubber bearings installed on top of a reinforced core structure. A multilevel structure is then suspended from a hat truss or umbrella girder constructed on the seismic isolation mechanism. The first building to use the CSI system was the Safety and Security Center in Tokyo, Japan, whose structural health monitoring system has detected and recorded 231 earthquake motions since 2006, including the 2011 Tohoku Pacific Earthquake (2011-TPE). The present study estimates the dynamic characteristics of this CSI-equipped building in earthquakes, and the effects of the CSI system are revealed via the observed earthquake records. The temporal changes of the fundamental period and damping factor are estimated from the 2011-TPE; the fundamental period increases with the deformation of the isolation level, whereas the fundamental damping factor is only related weakly to that deformation. The 231 observed earthquake records reveal that the CSI system performs seismic isolation by reducing the response acceleration of the suspended structure by roughly a half for peak ground accelerations exceeding 30 cm/s2. Daily microtremor observations are used to diagnose earthquake damage; the fundamental frequencies in each direction remain almost constant and were not changed by the 2011-TPE.

この論文で使われている画像

参考文献

1. Naeim F, Kelly J. Design of Seismic Isolated Structures: from theory to practice. John Wiley & Sons, Inc., New York,

1999.

2. Higasino M, Okamoto S. Response Control and Seismic Isolation of Buildings. Taylor & Francis, New York, 2006.

3. Saito Taiki [chair editor]. How to Plan and Implement Seismic Isolation for Buildings. Ohmsha, Tokyo, 2013.

4. Nakamura Y, Saruta M, Nakanishi T, Wada A, Takeuchi T, Hikone S, Takahashi T. Development of the

core-suspended isolation system. Proceedings of the 14th World Conference on Earthquake Engineering, Beijing,

China, 2008.

5. Nakamura Y, Saruta M, Wada A, Takeuchi T, Hikone S, Takahashi T. Development of the core-suspended isolation

system. Earthquake Engineering & Structural Dynamics 2011; 40(4): 429-447. doi:10.1002/eqe.1036.

6. Anderson P. Adaptive forgetting in recursive identification through multiple models. International Journal of Control

1985; 42(5):1175-1193.

7. Ljung L. System Identification. Prentice Hall, 1987.

8. Şafak E. Adaptive modeling, identification, and control of dynamic structural systems. I: Theory & II: Applications.

Journal of Engineering Mechanics 1989;115: 2386-2405 & 2406-2426.

9. Çelebi M, Şafak E. Seismic response of Transamerica Building. I: Data and Analysis & II: System Identification.

Journal of Structural Engineering 1991;117(8):2389-2425.

10. Şafak E. Identification of linear structures using discrete-time filters. Journal of Structural Engineering

1991;117(10): 3064-3085.

11. Çelebi M, Şafak E. Seismic response of Pacific Park Plaza. I: Data and Preliminary Analysis & II: System

Identification. Journal of Structural Engineering 1992;118(6): 1547-1589.

12. Çelebi M. Dynamic characteristics of five tall buildings during strong and low-amplitude motions. The Structural

Design of Tall Buildings 1993;2:1-15.

13. Şafak E. Response of a 42-storey steel-frame building to the Ms=7.1 Loma Prieta earthquake. Engineering

Structures;1993:15(6):403-421.

14. Saito Tomoo, Okada K, Yokota H. System identification of steel frame buildings through observed earthquake

records. Part I and II. Summaries of technical papers of Annual Meeting, Architectural Institute of Japan,

1994:673-676. (in Japanese)

15. Okada K, Yokota H. Dynamic characteristics of steel frame buildings using system identification technique,

Proceedings of the 9th Japan Earthquake Engineering Symposium 1994:1717-1722, Tokyo, Japan. (in Japanese)

16. Loh C, Tou I. A system identification approach to the detection of changes in both linear and non-linear structural

parameters. Earthquake Engineering & Structural Dynamics 1995;24(1):85-97.

17. Loh, C, Lin H. Application of off-line and on-line identification techniques to building seismic response data.

Earthquake Engineering & Structural Dynamics 1996;25(3):269-290.

18. Saito Tomoo, Yokota H. Evaluation of dynamic characteristics of high-rise buildings using system identification

techniques. Journal of Wind Engineering & Industrial Aerodynamics 1996;59(2-3)21:299-307.

19. Saito, Tomoo. System identification of a high-rise building applying multi-input-output ARX model of modal

analysis. Journal of Structural and Construction Engineering, Architectural Institute of Japan 1998;508:47-54. (in

Japanese)

19

20. Ikeda Y, Hisada Y. Earthquake responses on all floors in a building estimated by observation records on some

restricted floors. Journal of Japan Earthquake Engineering 2013;13(4):38-54. (in Japanese)

21. Siringoringo DM, Fujino Y. Long-term seismic monitoring of base-isolated building with emphasis on serviceability

assessment, Earthquake Engineering & Structural Dynamics 2015;44(4):637-655. doi:10.1002/eqe.2538.

22. Okada K, Shiraishi M, Iwaki H, Shiba K. Internet-based remote controlled structure monitoring system. Structural

Health Monitoring and Intelligent Infrastructure. Proceedings of the First International Conference SHMII-01,

Tokyo, Japan, 2003.

23. Okada K, Nakamura Y, Saruta M. Application of earthquake early warning system to seismic-isolated buildings.

Journal of Disaster Research 2009;4:570-578. doi:10.20965/jdr.2009.p0242.

24. Okada K, Kataoka S. Overall building response estimation method on records from two seismographs. The Journal

of Japan Association for Earthquake Engineering 2016;16:94-113.

25. Nakamura Y, Hanzawa T, Hasebe M, Okada K, Kaneko M, Saruta M. Report on the seismic isolation methods from

the 2011 Tohoku-Pacific Earthquake. Seismic Isolation and Protection Systems 2011;2:57-74.

26. Tomizawa T, Takahashi O, Suhara J, Okada K, Tsuyuki Y, Fujita T. A study on earthquake observation record in the

building using the three-dimensional seismic isolation system. Journal of Structural and Construction Engineering,

Architectural Institute of Japan 2012;679:1393-1402. (in Japanese)

27. Yoshimoto R, Mita A, Okada K. Damage detection of base-isolated buildings using multi-input multi-output

subspace identification. Earthquake Engineering & Structural Dynamics 2005;34:307-324. doi:10.1002/eqe.435.

20

...