1. Waksman, R. Lipinski, mj. Acampado, E. Cheng, Q. Adams, L. Torii, S. Gai, J. Torguson, R. Hellinga, D.M., Westman, P.C., Joner, M. Zumstein, P. Kolodgie, F.D., and Virmani, R.: Comparison of Acute Thrombogenicity for metallic and Polymeric Bioabsorbable scaffolds: Magmaris versus Absorb in a porcine arteriovenous shunt model. Circ Cardiovasc Interv, 10(8), Pii: e004762. Doi: 10, 2017. 1161/CIRCINTERVENTIONS. 116.004762.
2. Waksman, R. Zumstein, P. Pritsch, M. Wittchow, E. Haude, M. Lapointe-Corriveau, C. Leclerc, G. and Joner, M.: Second-generation magnesium scaffold Magmaris:device design and preclinical evaluation in a porcine coronary artery model. EuroIntervention. 13(4), 440-449, 2017.
3. Cheng, Y. Shibuya, M. McGregor, J. Conditt, G.B., Yi, G.H., Kaluza, G.L., Gray, W. Doshi, M. Sojitra, P. and Granada, J.F..: Biological effect on restenosis and vascular healing of encapsulated paclitaxel nanocrystals delivered via coated balloon technology in the familial hypercholesterolaemic swine model of in-stent restenosis. EuroIntervention. 12(9), 1164-1173, 2016.
4. Nakazawa, G. Torii, S. Ijichi, T. Nagamatsu, H. Ohno, Y. Kurata, F. Yoshikawa, A. Nakano, M. Shinozaki, N. Yoshimachi, F. and Ikari, Y.: Comparison of Vascular Responses Following New- Generation Biodegradable and Durable Polymer-Based Drug-Eluting Stent Implantation in an Atherosclerotic Rabbit Iliac Artery Model. J Am Heart Assoc. 5(10), pii: e003803, 2016.
5. Nakazawa, G. Shinke, T. Ijichi, T. Matsumoto, D. Otake, H. Torii, S. Hiranuma, N. Ohsue, T. Otsuka, F. Shite, J. Hirata, K. and Ikari, Y.: Comparison of vascular response between durable and biodegradable polymer-based drug-eluting stents in a porcine coronary artery model. EuroIntervention. 10(6), 717-723, 2014.
6. Kinoshita, Y. Kashima, Y. and Suzuki, T.: Directional coronary atherotomy – experimental use of single-blade cutting balloon. J Invasive Cardiol. 18(9), 428-431, 2006.
7. Ruiter, M.S., Doornbos, A. de Waard, V. Attevelt, N.J., Steendam, R. and de Vries, C.J.,: Long- term effect of stents eluting 6-mercaptopurine in porcine coronary arteries. J Negat Results Biomed. 15(1), 20, 2016.
8. Przemyslaw, K. Ruth, J.W. and Fernando, B.: VCSim3: VR simulator for cardiovascular interventions. Int J CARS. DOI10.1007/s11548-017-1679-1, 2017.
9. Saratzis, A. Calderbank, T. Sidioff, D. Bown, M.J., and Davies, R.S.,: Role of simulation in endovascular aneurysm repair (EV♙R) training: A preliminary study. Eur J Vasc Endovasc Surg. 53(2), 193-198, 2017.
10. Shilieto, K.E., Ganesan, P. Salmin, A.J., Cherry, E.M., Pertsov, A.M., and Ghoraani, B.: Catheter simulator software tool to generate electrograms of any multi-polar diagnostic catheter from 3D atrial tissue. Conf Proc IEEE Eng Med Biol Soc. 2741-2744, 2016..
11. Fresiello, L. Ferrari, G. Di Molfetta, A. Zielinski, K. Tzallas, A. Jacobs, S. Darowski, M. Kozarski, M. Meyns, B. Katertsidis, N.S., Karvounis, E.C., Tsipouras, M.G., and Trivella, M.G.,: A cardiovascular simulator tailored for training and clinical uses. J Biomed Informatics. 57, 100-112, 2015.
12. Nicole, V. Steven, D. Daniel, P. Doran, M. Karl, S. Kar,l A. and Ankur, C.: In vitro hemodynamic model of the arm arteriovenous circulation to study hemodynamics of native arteriovenous fistula and the distal revascularization and interval ligation procedure. J Vascular Surgery. 59, 1410-1417, 2014.
13. Nakano, T. Itoyama, T. Yoshida, K. Sawada, Y. Ikeda, S. Fukuda, T. Matsuda, T. Negoro, M. and Arai, F.: Multiscale fabrication of a transparent circulation type blood vessel simulator. Biomicrofluidics. 4, 046505, 2010.
14. Pantalos, G.M., Ionan, C. Koenig, S.C., Gillars, K.J., Horrell, T. Sahetya, S. Colyer, J. and Gray, L.A.,: Expanded pediatric cardiovascular simulator for research and training. ASAIO Journal. 67-72, 2010..
15. Gabriel, L. Alexander, D. Tom, C.N., Mara, B.A., jean, D.M., Michael, P.R., David, D.O., Leora, T.Y., Ara, A.V., and Eric, R.: Development and evaluation of a three-dimensional multistation cardiovascular simulator. Ann Thorac Surg. 102, 62-69, 2016.
16. Kimura, M. Nishimura, T. Kinoshita, O. Kashiwa, K. Kyo, S. and Ono, M.: Hemodynamic influence of tilting disc valve type on pump performance with the NIPRO-venticular assist device. J Artif Organs, 15(2), 134-139, 2012.
17. Funayama, N. Konishi, T. Yamamoto, T. and Hotta, D.: Coronary artery hematoma treated with fenestration using a novel NSE Alpha scoring balloon. Case Rep Cardiol. 2017:8189530, doi: 10, 1155/2017/8189530, 2017..
18. Ashida, K. Hayase, T. and Shinmura, T.: Efficacy of lacrosse NSE using the “leopard-crawl” technique on severely calcified lesions. J Invasive Cardiol, 25(10), 555-564, 2013.
19. Fujimura, T. Okamura, T. Ando, M. Uchida, K. Tone, T. Yonezawa, F. and Yano, M.: In vitro assessment of six aspiration catheters using a distal protection filter. Cardiol J. 23(6), 667- 672, 2016.
20. Voeltz, M.D., Nelson, M.A., McDaniel, M.C., and Manoukian, S.V.,: The important properties of contrast media: focus on viscosity. J Invasive Cardiol. 19(3), 1A-3A,