1. A. Guillon, J. Pardessus, P. Lhommetd, C Parenta, R. Respauda, D Marchand, J Montharuf, M. Montef, P. Janiakg, C. Boixelh, H. Audati, S. Huillei, E. Guillot and N Heuze-Vourc’h, Exploring the fate of inhaled monoclonal antibody in the lung parenchyma by microdialysis. Taylor & Francis Group, LLC, 11, 297-304 (2019).
2. Y. Lin, W. Huang, H. Tsai, M. Lee, Y. Chen, In vivo microdialysis and in vitro HPLC analysis of the impact of paeoniflorin on the monoamine levels and their metabolites in the rodent brain. BioMedicine, 11, 30-37, (2019).
3. P. Chang, Y. Zhang, D. Gonga, L. Yanga, J. Wanga, J Liua, W. Zhang, Determination of dexmedetomidine using high performance liquid chromatography coupled with tandem mass spectrometric (HPLC-MS/MS) assay combined with microdialysis technique: Application to a pharmacokinetic study. J. Chromatogr. B., 1160, 122381 (2020).
4. H. H. Nguyen, S H. Lee, U. J. Lee, C. D. Fermin and M. Kim, Immobilized Enzymes in Biosensor Applications. Materials, 12, (2019).
5. S. M. Abdullah and S Rachid, On Column Binding a Real -Time Biosensor for -lactam Antibiotics Quantification. Molecules, 25, (2020).
6. M. S. Goodwin, C. A. Mazefsky, S. Ioannidis, D. Erdogmus and M. Siegel, Predicting Aggression to Others in Youth With Autism Using a Wearable Biosensor. Autism Res., 12, 1286-1296 (2019).
7. Y. Wang, D. Mishra, J. Bergman, J. D Keighron, K. P Skibicka, A. Cans, Ultrafast Glutamate Biosensor Recordings in Brain Slices Reveal Complex Single Exocytosis Transients. ACS Chem., 10, 1744-1752 (2019).
8. M. Ganesana, E. Trikantzopoulos, Y. Maniar, S. T. Lee, B. J. Venton , Development of a novel micro biosensor for in vivo monitoring of glutamate release in the brain. Biosens Bioelectron., 130, 103-109 (2019).
9. C. R. Kahn, J. Roth, Berson, Yalow, and the JCI: the agony and the ecstasy. J Clin Invest., 114, 1051-1054 (2004).
10. R. D. Grange, J. P. Thompson, D. G. Lambert, Radioimmunoassay, enzyme and non-enzyme-based immunoassays. Br J Anaesth., 112, 213-216 (2014).
11. R. Bílek, T. Zelinka, P. Vlček, J. Dušková, D. Michalský, K. Novák, E. Václavíková, J. Widimský Jr, Radioimmunoassay of chromogranin A and free metanephrines in diagnosis of pheochromocytoma. Physiol Res., 66, S397-S408 (2017).
12. R. M. Heilmann, N. Grützner, S. Handl, J. S. Suchodolski, J. M. Steiner, Preanalytical validation of an in-house radioimmunoassay for measuring calprotectin in feline specimens. Vet Clin Pathol., 47, 100-107 (2018).
13. J. Y. Byun, K. H. Lee, Y. Shin, D. Kim, Cascading Amplification of Immunoassay Signal by Cell-Free Expression of Firefly Luciferase from Detection Antibody - Conjugated DNA in an Escherichia coli Extract. ACS Sens., 25, 93-99 (2019).
14. P. Du, M. Jin, G. Chen, C. Zhang, Z. Jiang, Y. Zhang, P. Zou, Y. She, F. Jin, H. Shao, S. Wang, L. Zheng, J. Wang, A Competitive Bio-Barcode Amplification Immunoassay for Small Molecules Based on Nanoparticles. Sci Rep., 6, 38114 (2016).
15. J. Y. Noh, S. Yoon, Y. Kim, T. V. Lo, M. Ahn, M. Jung, T. B. Le, W. Na, D. Song, V. P. Le, S. Haam, D. G. Jeong, H. K. Kim, Pipetting-based immunoassay for point-of-care testing: Application for detection of the influenza A virus. Sci Rep., 9. 16661 (2019).
16. Y. Wang, E. E. Dzakah, Y. Kang, Y. Cai, P. Wu, B. Tang, R. Li, X. He, A sensitive and rapid chemiluminescence immunoassay for point -of-care testing (POCT) of copeptin in serum based on high-affinity monoclonal antibodies via cytokine-assisted immunization. Int J Nanomedicine ., 14, 4293-4307 (2019).
17. K. Enpuku, K. Soejima, T. Nishimoto and H. Tokumitsu, Liquid phase immunoassay utilizing magnetic marker and high Tc superconducting quantum interference device. J. Appl. Phys., 100, 054701-1-054701-5 (2006).
18. K. Lu, C. Q. Vu, T. Matsuda, T. Nagai, Fluorescent Protein -Based Indicators for Functional Super-Resolution Imaging of Biomolecular Activities in Living Cells, Int J Mol Sci., 20, 5784 (2019).
19. E. A. Specht, E. Braselmann, A. E. Palmer, A Critical and Comparative Review of Fluorescent Tools for Live-Cell Imaging. Annu Rev Physiol ., 79, 93-117 (2017).
20. Z. Mai, J. Zhang, Y. Chen, J. Wang, X. Hong, Q. Su, X. Li, A disposable fiber optic SPR probe for immunoassay. Biosens Bioelectron., 144, 111621 (2019).
21. T. Horiuchi, T. Tobita, T. Miura, Y. Iwasaki, M. Seyama, S. Inoue, J. Takahashi, T. Haga, E. Tamechika, Floating chip mounting system driven by repulsive force of permanent magnets for multiple on-site SPR immunoassay measurements, Sensors (Basel)., 12, 13964-84 (2012).
22. Z. Lou, H. Han, M. Zhou, J. Wan, Q. Sun, X. Zhou and N. Gu, Fabrication of Magnetic Conjugation Clusters via Intermolecular Assembling for Ultrasensitive Surface Plasmon Resonance (SPR) Detection in a Wide Range of Concentrations. Anal Chem., 24, 13472-13479 (2017).
23. D. V. Sotnikov, A. V. Zherdev, B. B. Dzantiev, Detection of Intermolecular Interactions Based on Surface Plasmon Resonance Registration. Biochemistry (Mosc)., 13, 1820-1832 (2015).
24. J, Zhou, Q. Qi, C. Wang, Y. Qian, G. Liu, Y. Wang, L. Fu, Surface plasmon resonance (SPR) biosensors for food allergen detection in food matrices, Biosens Bioelectron., 142, 111449 (2019).
25. M. Puiu, C. Bala, SPR and SPR Imaging: Recent Trends in Developing Nanodevices for Detection and Real-Time Monitoring of Biomolecular Events. Sensors (Basel)., 6, 870 (2016).
26. D. Wang, F. Loo, H. Cong, W. Lin, S. K. Kong, Y. Yam, S. Chen, H. P. Ho, Real-time multi-channel SPR sensing based on DMD-enabled angular interrogation. Opt Express., 19, 24627-24636 (2018).
27. Y. Kim, J. Masson, K. S. Booksh, Single-crystal sapphire-fiber optic sensors based on surface plasmon resonance spectroscopy for in situ monitoring. Talanta, 5, 908-917 (2005).
28. X. Zhao, Y. Tsao, F. Lee, W. Tsai, C. Wang, T. Chuang, M. Wu, C. Lin, Optical fiber sensor based on surface plasmon resonance for rapid detection of avian influenza virus subtype H6: Initial studies. J Virol Methods., 233, 15-22 (2016).
29. H. Yu, Y. Chong, P. Zhang, J. Ma, D. Li, A D-shaped fiber SPR sensor with a composite nanostructure of MoS 2 -graphene for glucose detection. Talanta, 219, 121324 (2020).
30. S. Liu, S. Cao, Z. Zhang, Y. Wang, C. Liao, Y. Wang, Temperature Sensor Based on Side-Polished Fiber SPR Device Coated with Polymer. Sensors (Basel)., 19, 4063 (2019).
31. J. Pollet, F. Delport, K. P. Janssen, K. Jans, G. Maes, H. Pfeiffer, M. Wevers, J. Lammertyn, Fiber optic SPR biosensing of DNA hybridization and DNA-protein interactions. Biosens Bioelectron., 4, 864-869 (2009).
32. J. Lu, D. Spasic, F. Delport, T. V. Stappen, I. Detrez, D. Daems, S. Vermeire, A. Gils, J. Lammertyn, Immunoassay for Detection of Infliximab in Whole Blood Using a Fiber-Optic Surface Plasmon Resonance Biosensor. Anal Chem., 6, 3664-3671 (2017).
33. S. C. Jena, S. Shrivastava, S. Saxena, N. Kumar, S. K. Maiti, B. P. Mishra, R. K. Singh, Surface plasmon resonance immunosensor for label -free detection of BIRC5 biomarker in spontaneously occurring canine mammary tumours. Sci Rep., 1, 13485 (2019).
34. G. Borile, S. Rossi, A. Filippi, E. Gazzola, P. Capaldo, C. Tregnago, M. Pigazzi, F. Romanato, Label-free, real-time on-chip sensing of living cells via grating-coupled surface plasmon resonance. Biophys Chem., 254, 106262 (2019).
35. S. D. Soelberg, T. Chinowsky, G. Geiss, C. B. Spinelli, R. Stevens, S. Near, P. Kauffman, S. Yee, C. E. Furlong, A portable surface plasmon resonance sensor system for real-time monitoring of small to large analytes. J Ind Microbiol Biotechnol., 32, 11-12 (2005)
36. H. H. Nguyen, J. Park, S. Kang, M. Kim, Surface plasmon resonance: a versatile technique for biosensor applications. Sensors (Basel)., 5, 10481-10510 (2015).
37. A. Jilani, M. S. Abdel-wahab and A. H. Hammad, Advance Deposition Techniques for Thin Film and Coating. Intech, 65702, 137-149.
38. K. Niitsu, S. Ota, K. Gamo, H. Kondo, M. Hori, K. Nakazato , Development of Microelectrode Arrays Using Electroless Plating for CMOS-Based Direct Counting of Bacterial and HeLa Cells, IEEE Trans Biomed Circuits Syst ., 5, 607-619 (2015).
39. Y. Lei, H. Chen, H. Dai, Z. Zeng, Y. Lin, F. Zhou, D. Pang, Electroless -plated gold films for sensitive surface plasmon resonance detection of white spot syndrome virus. Biosens Bioelectron., 7, 1200-1207 (2008).
40. C. Xu, R. Zhou, H. Chen. X. Hou, G. Liu, Y. Liu, Silver -coated glass fibers prepared by a simple electroless plating technique. J Mater Sci., 25, 4638-4642 (2014).
41. L. Shen, J. Ji, J. Shen, Silver mirror reaction as an approach to construct superhydrophobic surfaces with high reflectivity. Langmuir., 18, 9962-9965 (2008).
42. A. François, J. Boehm, S. Y. Oh, T. Kok, T. M. Monr, Collection mode surface plasmon fibre sensors: a new biosensing platform. Biosens Bioelectron., 7, 3154-3159 (2011).
43. J. Boehm, A. François, H. E. Heidepriem, T. M. Monro, Chemical Deposition of Silver for the Fabrication of Surface Plasmon Microstructured Optical Fibre Sensors. 6, 133-136 (2011).
44. M. Loyeza, C. Ribauta, C. Caucheteurb, R. Wattieza, Functionalized gold electroless-plated optical fiber gratings for reliable surface biosensing. Sens. Actuators, B., 280, 54-61 (2019).
45. J. Zemek, Electron spectroscopy of corrugated solid surfaces, Anal Sci., 2, 177-186 (2010).
46. A. Carapelle, K. F. Frenette, J. P. Collette, H. P. Garnir, P. Harlet, Portable x -ray fluorescence spectrometer for coating thickness measurement. Rev Sci Instrum., 12, 123109 (2007).
47. Y. Gan, Atomic and subnanometer resolution in ambient conditions by atomic force microscopy. Surf. Sci. Rep., 64, 99-121 (2009).
48. A. Mohammed, A. Abdullah, Scanning Electron Microscopy (SEM): A Review, ResearchGate, ISSN 1454-8003 (2018).
49. N. P. Ahmadi, M. A. Khosravipour, Electroless Deposition of Ni -Cu-P Alloy on 304 Stainless Steel by Using Thiourea and Gelatin as Additives and Investigation of Some Properties of Deposits. International Journal of ISSI , 1, 29-34 (2004).
50. Y. Saito, J. J. Wang, D. N. Batchelder, D. A. Smith, Simple Chemical Method for Forming Silver Surfaces with Controlled Grain Sizes for Surface Plasmon Experiments. Langmuir., 19, 6857-6861 (2003).
51. Y. Aoki, K. Azumi, Optimization of Silver Mirror Reaction for Silver Coating. 表面 技術, 62 189-192 (2011).
52. S. Ekgasit, C. Thammacharoen, F. Yu, W. Knoll, Influence of the metal film thickness on the sensitivity of surface plasmon resonance biosensors. Appl Spectrosc., 59, 661-667 (2005).
53. Y. Zhao, Z. Denga, Q. Wanga, Fiber optic SPR sensor for liquid concentration measurement, Sens. Actuators, B., 192, 229-233 (2014).
54. Q. Liu, H. Yuan, Y. Liu, J. Wang, Z. Jing, W. Peng, J. Biomed. Opt., 2018, 23, 047003.
55. J. Zhao, S. Cao, C. Liao, Y. Wang, G. Wang, X. Xu, C. Fu, G. Xu, J. Lian, Y. Wang, Sens. Actuators B, 2016, 230, 206.
56. T. Hu, Y. Zhao, A. Song, Sens. Actuators B, 2016, 237, 521.
57. M. Mitsushio, K. Miyashita, M. Higo, Sensor properties and surface characteri zation of the metal-deposited SPR optical fiber sensors with Au, Ag, Cu, and Al. Sens. Actuators, A., 125, 296-303 (2006).
58. L. Tao, S. Deng, H. Gao, H. Lv, X. Wen, M. Li, Experimental Investigation of the Dielectric Constants of Thin Noble Metallic Films Using a Surface Plasmon Resonance Sensor. Sensors (Basel)., 5, 1505 (2020).
59. H. R. Gwon, S. H. Lee, Spectral and Angular Responses of Surface Plasmon Resonance Based on the Kretschmann Prism Configuration. Materials Transactions.,51. 1150-1155 (2010).
60. W. D. Li, J. Hu, S. Y. Chou, Extraordinary light transmission through opaque thin metal film with subwavelength holes blocked by metal disks. Opt Express., 21, 21098-21108 (2011).
61. S. A. Meyer, B. Auguié, E. C. Le Ru, P. G. Etchegoin, Combined SPR and SERS microscopy in the Kretschmann configuration. J Phys Chem A., 116, 1000-1007 (2012).
62. D. Chen, G. Fan, H. Zhang, L. Zhou, W. Zhu, H. Xi, H. Dong, S. Pang, X. He, Z. Lin, J. Zhang, C. Zhang, Y. Hao, Efficient Ni/Au Mesh Transparent Electrodes for ITO-Free Planar Perovskite Solar Cells, Nanomaterials (Basel) ., 9, 932 (2019).
63. K. Kurihara, K. Nakamura, K. Suzuki, Asymmetric SPR sensor response curve-fitting equation for the accurate detemination of SPR resonance angle. Sens. Actuators, B., 86, 49-57 (2002).
64. P. K. Maharana1, T. Srivastava, R. Jha1, Low index dielectric mediated surface plasmon resonance sensor based on graphene for near infrared measurements. J. Phys. D: Appl. Phys ., 47, 385102 (2014)
65. Z. Mai, J. Zhang, Y. Chen, J. Wang, X. Hong, Q. Su, X. Li, A disposable fiber optic SPR probe for immunoassay. Biosens Bioelectron., 144, 111621 (2019).
66. S. Shi, L. Wang, R. Su, B. Liu, R. Huang, W. Qi, Z. He, A polydopamine -modified optical fiber SPR biosensor using electroless-plated gold films for immunoassays. Biosens Bioelectron., 74, 454-460, (2015).
67. S. Shi, L. Wang, A. Wang, R. Huang, L. Ding, R. Su, W. Qiade, Z. Hea, Bioinspired fabrication of optical fiber SPR sensors for immunoassays using polydopamineaccelerated electroless plating. J. Mater. Chem. C., 4, 7554-7562 (2016).
68. G. Lou, Z. Chen, M. Zheng, Y. Liu, Mesenchymal stem cell-derived exosomes as a new therapeutic strategy for liver diseases. Exp Mol Med., 49, e346 (2017).
69. F. Deng, J. Miller, A review on protein markers of exosome from different bio-resources and the antibodies used for characterization. J Histotechnol ., 42, 226-239 (2019).
70. C. Grange, R. Skovronova, F. Marabese, B. Bussolati, Stem Cell -Derived Extracellular Vesicles and Kidney Regeneration. Cells., 8, 1240 (2019).
71. E. Lauwers, Y. Wang, R. Gallardo, R. V. Kant, E. Michiels, J. Swert s, P. Baatsen, S. S. Zaiter, S. R. McAlpine, N. V. Gounko, F. Rousseau., J. Schymkowitz, P. Verstreken, Hsp90 Mediates Membrane Deformation and Exosome Release. Mol Cell., 71, 689-702 (2018).
72. J. Meldolesi, Exosomes and Ectosomes in Intercellular Communicat ion, Curr Biol., 28, R435-R444 (2018).
73. L. Milane, A. Singh, G. Mattheolabakis, M. Suresh, M. M. Amiji, Exosome mediated communication within the tumor microenvironment. 219, 278 -294 (2015).
74. A. A. Sina, R. Vaidyanathan, S. Dey, L. G. Carrascosa, M. A Shiddi ky, M. Trau, Real time and label free profiling of clinically relevant exosomes. Sci Rep., 6, 30460 (2016).
75. J. Ko, M. A. Hemphill, D. Gabrieli, L. Wu, V. Yelleswarapu, G. Lawrence, W. Pennycooke, A. Singh, D. F. Meaney, D. Issadore, Smartphone -enabled optofluidic exosome diagnostic for concussion recovery. Sci Rep., 6, 31215 (2016).
76. R. Vaidyanathan, M. Naghibosadat, S. Rauf, D. Korbie, L. G. Carrascosa, M. J. Shiddiky, M. Trau, Detecting exosomes specifically: a multiplexed device based on alternating current electrohydrodynamic induced nanoshearing. Anal Chem.,86, 11125-11132 (2014).
77. P. Zhang, M. He, Y. Zeng, Ultrasensitive microfluidic analysis of circulating exosomes using a nanostructured graphene oxide/polydopamine coating. Lab Chip., 16, 3033-3042 (2016).